Field Erected Galvanized Steel Tanks w/NSF Coating

Field Erected Corrugated Galvanized Steel Tanks With "NSF" Approved Coatings & Liners

Potable Domestic Water Supply
Private and public water systems, campgrounds and resorts use NSF approved coated tanks for potable water storage applications. NSF coated tanks meet all Federal & State standards for storage of safe drinking water.

Fire Protection Reserve Water Storage
Many county and state fire departments recommend our tanks as economical alternatives to bolted or welded water tanks for fire protection storage.

Safety
Most field erected tanks meet seismic safety standards without anchoring, saving the expense of a concrete foundation. Set on a contained gravel foundation, wide diameters provide resistance to overturning without the need for seismic anchors. If anchoring is required or requested, American Tank Co. will provide a foundation design and submittal drawings with a California Civil Engineers wet stamp for building permits or customer approval.

Warranty & Savings Field Erected Corrugated tanks are baked by a one year manufacturer's warranty. Tanks are engineered, hot dipped mill galvanized and corrugated steel. These tanks are extremely cost effective when compared to bolted or welded steel tanks.

Irrigation Water Storage Farms and ranches throughout the west rely ATC tanks to maximize the efficiency of water well production and to control distribution and pumping cycles.

Size Field erected corrugated tanks are typically specified between 20,000 to 150,000 gallon capacities.

Erected on Site Field erected tanks come in sections and are erected on site. This makes the ATC tank an ideal choice for those hard to reach locations.



NSF
National Sanitation Foundation is an organization that certifies products that contact potable drinking water. This certification insures that only the absolute safest non toxic materials are used in the interior coating of our tanks. NSF certification meets or exceeds all Federal and State requirements.

Installation
Corrugated field erected tanks are assembled without the need for heavy equipment or flammable materials. Corrugated tank components can be trucked in, hand carried or dropped in by helicopter when grading of access roads is not possible or desirable. Please ask your sales representative for details and costs.

Service
Corrugated galvanized steel tanks have been manufactured in California for over 100 years. The normal service life is 25-30 years based on historical observations. With periodic maintenance, ATC tanks can provide 30 to 50 years of qualified service.

SPECIFICATIONS
Engineering
- Riveted Joint Design per A.I.S.C.
- Deck Supports and Live Loads per U.B.C.
- Prime Galvanized Steel per ASTM A527

Seam Sealant
- NSF Approved Urethane Polymer

Interior Tank Coating
- Farbertite is a Bituminous Ceramic Emulsion Coating a applied to the floor and side walls only. Interior roof coating available at additional charge.

Exterior Tank Coating (Optional)

- Acrylic Galvanized Steel Primer
- Acrylic Enamel Top Coat

Accessories Available

- Threaded (FNPT) Flanges
- 150# Steel Flanges
- Liquid Level Indicators
- Ladders
- Side Shell Manways
- Vents
- Gravel Rings
- Seismic Anchors


SPECIFICATIONS:

MATERIALS:

G-90 Prime Hot dipped galvanized carbon steel (1.25 oz. zinc/sq. ft.) ASTM A-527 Corrugations-2/3" pitch (o.c.) by 2/3" depth. Solid steel galvanized Tinners rivets (3/16" - 1/4" o.d.) ASTM-A525
RIVETS: EPA accepted, FDA approved Urethane Polymer
SEALANTS: Interior and Exterior bottom - Ceramic bitumastic butylene emulsion (standard) Exterior seams- - Aluminum based paint. Other coating systems available.
COATINGS:
Joint design per A.I.S.C. Tanks over 5,000 gallons may be seismically designed per section 12 of AWWA D-103-87 or 1991 UBC chapter 23.
ENGINEERING:

Depending on size and job location, certain tanks may require anchoring to concrete foundations. Tanks under 5,000 gallons are exempt from UBC regulations.

ACCESS:

STANDARD:

Published tank prices assume tank site is accessible by standard flat-bed truck or 4-Wheel drive pick-up and flat-bed trailer.

DIFFICULT:

Additional charges may be required for hand carrying of materials and equipment if vehicle access is not permissible.

DELIVERY:

ENGINEERING: Allow 2-3 weeks for preparation of engineering submittal.
MATERIALS: Allow 10-12* weeks from date of order (or approval) for delivery of materials to job site. * Subject to change based on current backlog.
ERECTION: Allow 5-10 working days for completion of tank erection depending on weather and access conditions.

SHIPPING & HANDLING: Please ask your sales representative for shipping & handling quote.


TANK FLANGES AVAILABLE:
(Inlets, Outlets, Overflow, & Control Ports):

FNPT Female Flanges: 1/2" thru 6"
125# NPT Companion Flanges: 1" thru 8"
150# RFSO Companion Flanges: 3" thru 12"

ADDITIONAL ACCESSORIES:
We manufacture or supply the following typical tank appurtenances: Gravel containment rings, Liquid level indicators, Sight gauges, Tank ladders, Tank vents, Hinged deck manways, Shell manways, Seismic anchors, Float valves, Gate valves, Fire department adapters, Fire protection equipment, Hydrants, etc. See Accessory Price List for more information.

FIELD ERECTED TANK PRICE EXCLUSIONS:
Price List does not include grading, foundations, tank appurtenances, applicable freight charges, hard access fees or State and Local Sales Taxes. Building permits if required, shall be obtained by owner or owners agent.


The following is a list of recently installed Corrugated Galvanized Water Storage Tanks*:

CLIENT

LOCATION

CAPACITY

Mendocino Middle School Mendocino, CA 60,000 Gal.
USDA Forest Service Bass Lake Camp, CA 20,800 Gal.
Table Mountain Rancheria Friant, CA 67,900 Gal.
Santa Clara Parks and Rec. Morgan Hill, CA 10,000 Gal.
Cedar Smoke School Truckee, CA 101,350 Gal
Catholic Youth Organization Occidental, CA 101,350 Gal.
USDA Forest Service Oakhurst, CA 10,000 Gal.
Hidden Valley Foodmart Middletown, CA 31,000 Gal.
Silver Oak Cellars Geyserville, CA 30,500 Gal.
MCI Telecommunications Hayward, CA 22,750 Gal.
Thompson Orchard Hood River, CA 31,000 Gal.
Mission Springs Conference Center Scotts Valley, CA 67,900 Gal.
Agri-Cell, Inc. Delano, CA 15,000 Gal.
Agri-Cell, Inc. Delano, CA 10,000 Gal.
Bennett Ridge Mutual Water Company Santa Rosa, CA 51,000 Gal.
Grass Valley Assembly of God Grass Valley, CA 2 - 12,000 Gal.
Diamond Arrow Conference Center Nevada City, CA 67,900 Gal.
Sequoia Construction Whitehorn, CA 10,000 Gal.
Medite Corporation Medford, CA 10,650 Gal.
Kendall Jackson Winery Geyserville, CA 12,000 Gal.
Verde River R.R. Depot Clarksdale, CA 10,000 Gal.
Eagle Ridge Subdivision Show Low, CA 53,500 Gal.
City of Depoe Bay Depoe Bay, CA 10,000 Gal.

*Customer referrals available upon request only.


Important Customer Notice:
Foundation Requirements For Field Erected
Storage Tanks

When installing your Gravel Ring Foundation, it is mandatory that
ONLY 3/4" Crushed Rock be used.
Do Not Use Pea Gravel.

Failure to use 3/4" Crushed rock in your tanks foundation, will result in time delays and additional labor charges while our erection crew waits onsite for the proper rock to be installed.


Thank you,

American Tank Company, Inc.